Chapter G >> Migration Done --Suniti (discussion) 30 mai 2016 à 21:38 (EDT)
Points to check
To do for Laurent
Mix 3 pages Protection, Coupure et Sectionnement Protection du conducteur neutre --Romain.R (discussion) 6 juin 2016 à 11:07 (EDT)
Text Format changed >> to be confirmed
- Pdf pg G5 >> Détermination de la protection
- I think a table willl be better, with In lab first column and K3 label for the 2nd column --Romain.R (discussion) 8 juin 2016 à 08:12 (EDT)
- Romain :
- I think the "grey section" in the book (french specific section in the wiki) is at the wrong place, as it seems to be related to "protection par fusible" and not to "Association de dispositif ..."
- and yes, this text is not looking good, AND is really hard to understand
- please check with Denis ho to re-formulate
- Suniti can you already change the K3 in proper format k3
- --LMischler (discussion) 14 juin 2016 à 13:42 (EDT)
Extra text is coming and note points are not aligned properly
- Pdf pg G5 >> Fig G6 >> Détermination de la protection#Règle générale
- Laurent to check, pb with template
- I finally found the problem ... took me quite some time
- it comes from a missing </p> in a bullet list with extra content paragraph in it, just before this figure
- Suniti : can you please check other similar problems, to confirm it is the same type of issue
- --LMischler (discussion) 14 juin 2016 à 13:20 (EDT)
FR Tables content different from EN tables >> To be checked with Denis
- Fig G12 (one row is missing in FR)
- Fig G13 (one row is missing in FR)
- Fig G17 (one number is different)
- Fig G20 (One coloumn of text is extra in EN, numbers are very different and 6 images in FR while 7 in EN )
- Fig G22 (one extra column in EN)
- Fig G36 (Note: Formula added in EN, also added here but still some content is different)
- Fig G37 (Note: Formula added in EN, also added here but still some content is different)
- Fig G39 (formula in the table note is different)
- Fig G52
- Fig G58 (position of table rows is different)
- Fig G59 (minor number change)
- Fig G63
Changes in EN WIKI
- No navigation panel in EN (Module 4.4)PDF pg G30
- PDF pg G33 >> Change in formula (≤ instead of ≥)
- Laurent: check EN wiki, there are mistakes
PDF pg G32 >> Fig G42b >> (1) and (2) are footnotes ?
Footnote text is missing
- PDF pg G41
- Reference added --Suniti (discussion) 1 juin 2016 à 03:55 (EDT)
Table notes format to be checked
- Pdf pg G46 >> fig G63 Sectionnement du conducteur neutre
- to see with laurent, migration of 7.2, 7.3, 7.4--Romain.R (discussion) 6 juin 2016 à 08:43 (EDT)
Table footnote is there in En but not in FR
- Pdf pg G48 >> Fig G63c
images to be checked (For Laurent )
- Fig G20 (Extra image in EN)
DONE
- Fig Gf17 >> text added with image
Sub sub-bullets used
Changed to Level 3/Level 4
- Pdf pg G5 >> Détermination de la protection
- Pdf pg G6 >> Emplacement des protections
- Pdf pg G12 >> Méthode générale de dimensionnement des canalisations#Facteurs de correction
- PDF pg G57 >> Méthode générale de dimensionnement des canalisations
- Ok for me--Romain.R (discussion) 8 juin 2016 à 08:06 (EDT)
Note points >> Position to be checked
- ok , checked
Text Format changed >> to be confirmed
- PDF pg G50 >> Fig Gf2
- ok, checked --Romain.R (discussion) 8 juin 2016 à 08:31 (EDT)
Bullet points added to following pages
- PDF pg G4 >> Principe de la protection des circuits contre les surintensités
- PDF pg G25 >> Courant de court-circuit triphasé au secondaire d'un transformateur MT/BT
- PDF pg G56 >> Détermination de la section des canalisations non enterrées
- PDF pg G59 >> Détermination de la section des canalisations enterrées
- PDF pg G60 >> (chaged "-" to sub-bullets) Détermination de la section des canalisations enterrées#Exemple 4