Discussion:La protection contre les surtensions
De Guide de l'Installation Electrique
Chapter J >> Migration Done
--Suniti (discussion) 7 juin 2016 à 22:28 (EDT)
points to look at
fig.J37 obsolete and to be replaced by up-to-date figure
- new source image provided in box by Laurent
- Suniti to convert
- Romain to check
- New image uploaded --Suniti (discussion) 4 juillet 2016 à 00:06 (EDT)
Pdf pg J16 >> Fig J24 >> To be checked as there is difference between EN and FR ( coloumn 6, Row 4)
Caractéristiques communes des parafoudres suivant les caractéristiques de l’installation
- Triphased Law, Laurent to check for you EN if you want to change--Romain.R (discussion) 14 juin 2016 à 04:33 (EDT)
- Romain I quickly checked the standard to see how it was presented there
- the problem is that our table is obsolete: table 53C does not exist anymore, it is now table 534.2 and it is different
- I think you should check this with Denis and I will do the same with corporate contact
- --LMischler (discussion) 17 juin 2016 à 04:22 (EDT)
Fig J36 (to be checked as size of the images is not proper)
- for me, it will be better to have the same size, better look (like the booth in the middle)--Romain.R (discussion) 15 juin 2016 à 09:57 (EDT)
- done, had to reconvert 2 of the 4 images for coherence + resized images in table code (+ vertical position = bottom) --LMischler (discussion) 22 juin 2016 à 10:18 (EDT)
future improvements
Table in Fig.J26 : SVG icon images with white background is not looking good
- Laurent to check if transparency can be used OR if we convert to GIF
review table in fig J48
- to avoid specific grey background, in first column in particular --LMischler (discussion) 17 juin 2016 à 04:22 (EDT)
Problems detected in the book
PDF pg J25 >> Correction in PDF (the text is not in superscript)
DONE
Issue with Image J26 (SVG are not coming properly >> To be checked with Laurent)
- problem solved (SVG generated by Illustrator was not OK, found a turnaround) => images are now uploaded
Level 3/ Level 4
- PDF pg J9 >> Système de protection foudre de l’installation électrique
- PDF pg J10 >> Le parafoudre#Les trois types de parafoudre
- PDF pg J11 >> Le parafoudre#Caractéristiques des parafoudres
- PDF pg J13 >> Règle de conception de la protection foudre
- Pdf pg J18 >> Caractéristiques communes des parafoudres suivant les caractéristiques de l’installation#Nombre de pôles
- PDF pg J20 >> Choix des dispositifs de déconnexion#Caractéristiques du dispositif de déconnexion externe
- PDF pg J31 >> Normes des protections foudre
ok, checked --Romain.R (discussion) 14 juin 2016 à 04:42 (EDT)
Pdf pg J18 >> Fig J28 >> No table note text for the two references
- translation must be check with denis :[1] la protection entre la phase et le neutre peut aussi bien être inclue dans le parafoudre en amont de l'installation, ou alors à distance proche de l'équipement à proteger. [2] si neutre distribué --Romain.R (discussion) 14 juin 2016 à 04:27 (EDT)
Bullet Points
- Pdf pg J20 >> Removed bullet point >> Choix d’un parafoudre de type 2
- Pdf pg J31 >> Bullet points added >> Les composants d’un parafoudre
- checked --Romain.R (discussion) 14 juin 2016 à 04:22 (EDT)